Get a Quote

OF6914 MTP-LC Duplex Breakout Cable, 12F, OM4, OFNP, Type B, 3m

Catalog No
OF6914
Fiber Type
OM4
Fiber Count
12 Fibers
Sheath Material
OFNP
Polarity Configuration
Type B

MTP-LC Duplex Breakout Cable, 12F, OM4, OFNP, Type B, 3m delivers high-speed, low-loss multimode connectivity for 40G/100G networks, featuring a plenum-rated jacket for safe deployment in air-handling environments. Stanford Advanced Materials (SAM) is a trusted global supplier of advanced optical and electronic materials, known for precision-engineered solutions that meet the demands of modern data infrastructure.

INQUIRE NOW
MTP-LC Duplex Breakout Cable
MTP-LC Duplex Breakout Cable
Description
Specifications
Reviews

MTP-LC Duplex Breakout Cable Description

MTP-LC Duplex Breakout Cable, 12F, OM4, OFNP, Type B, 3m is a high-performance fiber optic solution designed for high-density, short-range multimode applications in plenum spaces. Featuring OM4 50/125 μm multimode fiber, this cable supports high-speed data transmission including 40G and 100G Ethernet, with enhanced modal bandwidth and low insertion loss. It is equipped with a female MTP connector on one end and six duplex LC connectors on the other, offering efficient breakout from backbone cabling to active equipment. The Type B polarity ensures proper signal alignment, while the OFNP (plenum-rated) jacket provides the highest level of flame resistance for safe installation in air-handling environments. Every cable is 100% factory-terminated and tested, ensuring superior performance and reliability in mission-critical network infrastructures.

MTP-LC Duplex Breakout Cable Applications

Data Centers

Enterprise Networks

Telecommunications

Healthcare, Education, and Government Facilities

MTP-LC Duplex Breakout Cable Packaging

Our products are packaged in customized cartons of various sizes based on the material dimensions. Small items are securely packed in PP boxes, while larger items are placed in custom wooden crates. We ensure strict adherence to packaging customization and the use of appropriate cushioning materials to provide optimal protection during transportation.

Packaging: Carton, Wooden box, Paper barrel, Iron barrel, or Customized.

Product Features

Read more: OM1 vs OM2 vs OM3 vs OM4 vs OM5: Multimode Fiber Cable Differences

Specifications

Fiber Count

12 Fibers

Sheath Material

OFNP

Polarity Configuration

Type B

Standards

IEC 61754-7

IEC 61754-20

IEC 61300-3-4

TIA/EIA-568-C.3

ISO/IEC 11801

Fiber Performance

Fiber Type

OM4

Core/Cladding Diameter (μm)

50/125

Effective Modal Bandwidth (MHz·km)

4700

Operating Wavelength (nm)

850 / 1300

Maximum Attenuation (dB/km)

2.3 / 0.6

Connector Performance

Loss Grade

MTP Multimode High Precision

IL (Insertion Loss, dB)

≤ 0.25

High-Low Temperature Cycle ΔIL (dB)

≤ 0.20

RL (Return Loss, dB)

≥ 28

High-Low Temperature Cycle ΔRL (dB)

≤ 5

Mechanical Properties

Number of Optical Fibers

12 fibers

Min. Static Bending Radius

10D mm

Min. Dynamic Bending Radius

20D mm

Operating Temperature

-20~+60 °C

Installation Temperature

-5~+50 °C

Storage and Transport Temperature

-25~+75 °C

*The above product information is based on theoretical data. For specific requirements and detailed inquiries, please contact us.

Customer Reviews Write a review
0
(0 Reviews)
5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Stars
0
No reviews for current products.
FAQ
Q1: What type of fiber is used in this cable?

A1: It uses OM4 multimode fiber (50/125 μm), optimized for short-reach, high-speed transmissions such as 40G/100G Ethernet.

Q2: What connectors are featured?

A2: The cable has one MTP female connector on one end and six duplex LC connectors on the other, supporting 12 fibers.

Q3: What does "Type B polarity" mean?

A3: Type B polarity provides straight-through fiber mapping, aligning transmit and receive channels correctly for duplex communication.

Q4: What is the OFNP rating?

A4: OFNP (Optical Fiber Nonconductive Plenum) is the highest flame-resistance rating for indoor fiber optic cables, making it suitable for use in air-handling spaces such as plenum ceilings and ducts.

Get a Quote

Send us an inquiry now to find out more information and the latest prices, thanks!
Product Name
Your Name
Your Phone
Your Email
Country
United States
  • United States
  • Afghanistan
  • Aland Islands
  • Albania
  • Algeria
  • American Samoa
  • Andorra
  • Angola
  • Anguilla
  • Antarctica
  • Antigua and Barbuda
  • Argentina
  • Armenia
  • Aruba
  • Australia
  • Austria
  • Azerbaijan
  • Bahamas
  • Bahrain
  • Bangladesh
  • Barbados
  • Belarus
  • Belgium
  • Belize
  • Benin
  • Bermuda
  • Bhutan
  • Bolivia
  • Bosnia and Herzegovina
  • Botswana
  • Bouvet Island
  • Brazil
  • British Indian Ocean Territory
  • British Virgin Islands
  • Brunei
  • Bulgaria
  • Burkina Faso
  • Burundi
  • Cambodia
  • Cameroon
  • Canada
  • Cape Verde
  • Cayman Islands
  • Central African Republic
  • Chad
  • Chile
  • China
  • Christmas Island
  • Cocos (Keeling) Islands
  • Colombia
  • Comoros
  • Congo
  • Cook Islands
  • Costa Rica
  • Croatia
  • Cuba
  • Cyprus
  • Czech Republic
  • Democratic Republic of Congo
  • Denmark
  • Disputed Territory
  • Djibouti
  • Dominica
  • Dominican Republic
  • East Timor
  • Ecuador
  • Egypt
  • El Salvador
  • Equatorial Guinea
  • Eritrea
  • Estonia
  • Ethiopia
  • Falkland Islands
  • Faroe Islands
  • Federated States of Micronesia
  • Fiji
  • Finland
  • France
  • French Guyana
  • French Polynesia
  • French Southern Territories
  • Gabon
  • Gambia
  • Georgia
  • Germany
  • Ghana
  • Gibraltar
  • Greece
  • Greenland
  • Grenada
  • Guadeloupe
  • Guam
  • Guatemala
  • Guinea
  • Guinea-Bissau
  • Guyana
  • Haiti
  • Heard Island and Mcdonald Islands
  • Honduras
  • Hong Kong
  • Hungary
  • Iceland
  • India
  • Indonesia
  • Iran
  • Iraq
  • Iraq-Saudi Arabia Neutral Zone
  • Ireland
  • Israel
  • Italy
  • Ivory Coast
  • Jamaica
  • Japan
  • Jordan
  • Kazakhstan
  • Kenya
  • Kiribati
  • Kuwait
  • Kyrgyzstan
  • Laos
  • Latvia
  • Lebanon
  • Lesotho
  • Liberia
  • Libya
  • Liechtenstein
  • Lithuania
  • Luxembourg
  • Macau
  • Macedonia
  • Madagascar
  • Malawi
  • Malaysia
  • Maldives
  • Mali
  • Malta
  • Marshall Islands
  • Martinique
  • Mauritania
  • Mauritius
  • Mayotte
  • Mexico
  • Moldova
  • Monaco
  • Mongolia
  • Montenegro
  • Montserrat
  • Morocco
  • Mozambique
  • Myanmar
  • Namibia
  • Nauru
  • Nepal
  • Netherlands Antilles
  • Netherlands
  • New Caledonia
  • New Zealand
  • Nicaragua
  • Niger
  • Nigeria
  • Niue
  • Norfolk Island
  • North Korea
  • Northern Mariana Islands
  • Norway
  • Oman
  • Pakistan
  • Palau
  • Palestinian Territories
  • Panama
  • Papua New Guinea
  • Paraguay
  • Peru
  • Philippines
  • Pitcairn Islands
  • Poland
  • Portugal
  • Puerto Rico
  • Qatar
  • Reunion
  • Romania
  • Russia
  • Rwanda
  • Saint Helena and Dependencies
  • Saint Kitts and Nevis
  • Saint Lucia
  • Saint Pierre and Miquelon
  • Saint Vincent and the Grenadines
  • Samoa
  • San Marino
  • Sao Tome and Principe
  • Saudi Arabia
  • Senegal
  • Serbia
  • Seychelles
  • Sierra Leone
  • Singapore
  • Slovakia
  • Slovenia
  • Solomon Islands
  • Somalia
  • South Africa
  • South Georgia and South Sandwich Islands
  • South Korea
  • Spain
  • Spratly Islands
  • Sri Lanka
  • Sudan
  • Suriname
  • Svalbard and Jan Mayen
  • Swaziland
  • Sweden
  • Switzerland
  • Syria
  • Taiwan
  • Tajikistan
  • Tanzania
  • Thailand
  • Togo
  • Tokelau
  • Tonga
  • Trinidad and Tobago
  • Tunisia
  • Turkey
  • Turkmenistan
  • Turks And Caicos Islands
  • Tuvalu
  • US Virgin Islands
  • Uganda
  • Ukraine
  • United Arab Emirates
  • United Kingdom
  • United States
  • United States Minor Outlying Islands
  • Uruguay
  • Uzbekistan
  • Vanuatu
  • Vatican City
  • Venezuela
  • Vietnam
  • Wallis and Futuna
  • Western Sahara
  • Yemen
  • Zambia
  • Zimbabwe
Comments
I would like to join the mailing list to receive updates from Stanford Optics.
Attach Drawing:
Drop files here or
Upload your File
Accepted file types: PDF, PNG, JPG, JPEG. Upload multiple files at once; Each file must be under 2MB.
Check Code

E-mail address with your company's domain name is preferred. Otherwise, we may not be able to process your inquiry.

Please fill in the required fields.